Millisecond level response speed of BESS controller;
Multiple ESS control functionalities;
Compatible communication interface with battery management system (BMS);
Proprietary versatile control algorithms and logics;
Control can be realized in either ESS controller or PCS control software;
Built-in transient fault recorder function for fault tracking and system analysis;
Hundreds of communication protocols are supported;
Work with different renewable energy for smoothing the power generation;
Manual operation;
Anti-islanding operation;
Black start/ island operation;
Frequency regulation control;
The other functions required by grid requirement;
716.8V 1000KW/1.55MWh
Please read the user manual carefully before operating!
Module Specifications
No. | Part Number | WDLFP-51.2V11.1K-P |
1 | Energy storage | 11.1KWh |
2 | Rated Voltage | 51.2V/DC |
3 | Maximum Charge Voltage | 57.6V/DC |
4 | Discharge Cut-off Voltage | 40V/DC |
5 | Configuration | 16S7P |
6 | ESR/AC @1KHz 50% SOC | <10mΩ |
7 | Max. Continuous Current | 140A |
8 | Max. Power | 7.168KW |
9 | Charge Temperature | 0℃~+55℃ |
10 | Discharge Temperature | -20℃~+60℃ |
11 | Recommended Depth of Discharge | 5%~90% |
12 | Maximum Depth of Discharge | 100% |
13 | Operating Humidity | 0~90% RH Non-condensing |
14 | Cells Self-discharge Rate | 3% per month |
15 | Cooling Method | natural cooling |
16 | Shell Material | Metal |
17 | Communicate Method | CAN |
18 | Monitoring Data | Module voltage,SOC,current,temperature,cell’s voltage |
19 | Output Terminal | Connector |
20 | Weight | 130Kg |
21 | Dimensions(W*D*H) | 690*790*133mm |
Module Drawing
Rack String Specifications
No. | Part Number | WDLFP-716.8V155.4K-R |
1 | Energy storage | 155.4KWh |
2 | Rated Voltage | 716.8V/DC |
3 | Maximum Charge Voltage | 806.4V/DC |
4 | Discharge Cut-off Voltage | 627.2V/DC |
5 | Configuration | 224S7P (14sets above module series connection) |
6 | ESR/AC @1KHz 50% SOC | <140mΩ |
7 | Max. Continuous Current | 140A |
8 | Max. Power | 100KW |
9 | Weight | 1820Kg |
10 | Dimensions(W*D*H) | 740*860*2165mm |
Rack String Dimensions and Layout
Containered Battery Energy Storage System Specifications
No. | Part Number | WDLFP-716.8V1000KW/1.55MWh-C |
1 | Energy storage | 1.554MWh |
2 | Rated Voltage | 716.8V/DC |
3 | Maximum Charge Voltage | 806.4V/DC |
4 | Discharge Cut-off Voltage | 627.2V/DC |
5 | Configuration | 224S7P*10 (10units strings parallel connection) |
6 | ESR/AC @1KHz 50% SOC | <50mΩ |
7 | Max. Continuous Current | 1400A |
8 | Max. Power | 1000KW |
9 | Charge Temperature | 0℃~+55℃ |
10 | Discharge Temperature | -20℃~+60℃ |
11 | Recommended Depth of Discharge | 5%~95% |
12 | Maximum Depth of Discharge | 100% |
13 | Operating Humidity | 0~90% RH Non-condensing |
14 | Cooling Method | natural cooling |
15 | Weight | 18200Kg (not including container and PCS) |
16 | Dimensions(W*D*H) | 740*860*2165mm*10sets |
Unique Balancing Technologies
· Non-destructive active balancing
· High balancing current, almost no heat dissipation
· Balancing regardless of circumstances
Smart Management System
· High accuracy voltage detection
· High accuracy current detection
· High current non-destructive active balance
· High efficiency balancing strategy
· Multi-protection
· Applicable SoC estimation
· High reliability
· Intellectual BMS interface
· Historical event slog
Main Characters of BMS
· Highly precise current temperature
· High efficient balance controlling
· Highly precise voltage inspection
· Active balance for heavy current
· Multiple protection for safety
· Practical evaluation of SOC
· Records of historical events
· Better user experience
· Smart BMS interface
· High reliability
Completely Integrated System (for reference only)
FSS introduction
Loop of multiple FSS solution with FDMC
20kW indoor vertical mounted HVAC
Parameters Model | Unit | MC200HCNC1A |
Dimensions, Weight & Mount | ||
External Dimensions (Width x Depth x Height )With Flange | mm | 800×650×2100 |
Weight | kg | 260 |
Mounting Method | Indoor | |
Application | Indoor | |
Environmental Protection & Performance | ||
Working Temperature Range | ºC | -30 to +45 |
Noise Level | dB(A) | 75 |
Refrigerant | R410A | |
RoHS Compliant | Yes | |
Cooling/Heating Capacity | ||
Cooling Capacity@L27(50%)/L35 | kW | 28 |
Heating Capacity | kW | 8 |
Consumption Power | ||
Power input of cooling@l27 (50%)/L35 | kW | 10 |
Heating input power | kW | |
Air supply | ||
air supply volume | m3/h | 6600 |
Power Supply | ||
Power Supply range | V, Hz | 380-415±10%,3N~,50 |
Rated operating voltage - Controller | V, Hz | 380-415,3N~,50 |
Rated operating voltage - Cooling/Heating | Hz | 380-415,3N~,50 |
Current Max. | A | 40 |
Key Components | ||
Controller | Envicool | |
Fans | Telecom Level | |
Compressor | Telecom Level | |
Heater | Telecom Level |
PCS introduction
Sinexcel PWG2-50K-NA 5sets
·Modular design and wide power range in
·single cabinet
·Bi-directional Power Conversion System
·Built-in transformer
·Grid-support functions
·Flexible configuration
·Support PV access
Compliance
UL1741 /UL 9540, CPUC RULE 21,IEEE1547,CSA 22.2
Please reference the datasheet.
EMS
EMS will achieve the load monitor and send command to PCS to adjust the output power to
response load requirement.
Actual scene diagram
Caution
Place the module out of the reach of children and infants.
Do not place the module in microwave ovens or other similar appliances.
Do not remove the product label.
Do not attempt to open or service the battery pack.
Do not expose to temperatures above 80℃.
Do not short-circuit the positive and negative terminals of the battery with wire or other metallic objects.
Do not transport or store the module with metallic items.
Do not expose the module to direct heat or flame, and do not use or store it near a fire or a location, subject to high temperatures. In addition, do not immerse or dampen the module in water, saltwater, or any other liquid.
Do not puncture the module with any sharp objects, hit it with a hammering device or similar device, step on it, drop it or subject it to strong shock.
Do not use module if it is damaged or deformed.
Immediately cease use of the module if it produces strange smells or smokes or becomes abnormally hot.
If the module fluids leak and come into contact with an eye, do not rub the eye and immediately flush it with plenty of water before seeking medical assistance.
Notes
The pictures in the file are only for reference.
We reserve the final explanations of the items in this specification. This proposal is applicable for prototype.
Specifications subject to change without notice
Millisecond level response speed of BESS controller;
Multiple ESS control functionalities;
Compatible communication interface with battery management system (BMS);
Proprietary versatile control algorithms and logics;
Control can be realized in either ESS controller or PCS control software;
Built-in transient fault recorder function for fault tracking and system analysis;
Hundreds of communication protocols are supported;
Work with different renewable energy for smoothing the power generation;
Manual operation;
Anti-islanding operation;
Black start/ island operation;
Frequency regulation control;
The other functions required by grid requirement;
716.8V 1000KW/1.55MWh
Please read the user manual carefully before operating!
Module Specifications
No. | Part Number | WDLFP-51.2V11.1K-P |
1 | Energy storage | 11.1KWh |
2 | Rated Voltage | 51.2V/DC |
3 | Maximum Charge Voltage | 57.6V/DC |
4 | Discharge Cut-off Voltage | 40V/DC |
5 | Configuration | 16S7P |
6 | ESR/AC @1KHz 50% SOC | <10mΩ |
7 | Max. Continuous Current | 140A |
8 | Max. Power | 7.168KW |
9 | Charge Temperature | 0℃~+55℃ |
10 | Discharge Temperature | -20℃~+60℃ |
11 | Recommended Depth of Discharge | 5%~90% |
12 | Maximum Depth of Discharge | 100% |
13 | Operating Humidity | 0~90% RH Non-condensing |
14 | Cells Self-discharge Rate | 3% per month |
15 | Cooling Method | natural cooling |
16 | Shell Material | Metal |
17 | Communicate Method | CAN |
18 | Monitoring Data | Module voltage,SOC,current,temperature,cell’s voltage |
19 | Output Terminal | Connector |
20 | Weight | 130Kg |
21 | Dimensions(W*D*H) | 690*790*133mm |
Module Drawing
Rack String Specifications
No. | Part Number | WDLFP-716.8V155.4K-R |
1 | Energy storage | 155.4KWh |
2 | Rated Voltage | 716.8V/DC |
3 | Maximum Charge Voltage | 806.4V/DC |
4 | Discharge Cut-off Voltage | 627.2V/DC |
5 | Configuration | 224S7P (14sets above module series connection) |
6 | ESR/AC @1KHz 50% SOC | <140mΩ |
7 | Max. Continuous Current | 140A |
8 | Max. Power | 100KW |
9 | Weight | 1820Kg |
10 | Dimensions(W*D*H) | 740*860*2165mm |
Rack String Dimensions and Layout
Containered Battery Energy Storage System Specifications
No. | Part Number | WDLFP-716.8V1000KW/1.55MWh-C |
1 | Energy storage | 1.554MWh |
2 | Rated Voltage | 716.8V/DC |
3 | Maximum Charge Voltage | 806.4V/DC |
4 | Discharge Cut-off Voltage | 627.2V/DC |
5 | Configuration | 224S7P*10 (10units strings parallel connection) |
6 | ESR/AC @1KHz 50% SOC | <50mΩ |
7 | Max. Continuous Current | 1400A |
8 | Max. Power | 1000KW |
9 | Charge Temperature | 0℃~+55℃ |
10 | Discharge Temperature | -20℃~+60℃ |
11 | Recommended Depth of Discharge | 5%~95% |
12 | Maximum Depth of Discharge | 100% |
13 | Operating Humidity | 0~90% RH Non-condensing |
14 | Cooling Method | natural cooling |
15 | Weight | 18200Kg (not including container and PCS) |
16 | Dimensions(W*D*H) | 740*860*2165mm*10sets |
Unique Balancing Technologies
· Non-destructive active balancing
· High balancing current, almost no heat dissipation
· Balancing regardless of circumstances
Smart Management System
· High accuracy voltage detection
· High accuracy current detection
· High current non-destructive active balance
· High efficiency balancing strategy
· Multi-protection
· Applicable SoC estimation
· High reliability
· Intellectual BMS interface
· Historical event slog
Main Characters of BMS
· Highly precise current temperature
· High efficient balance controlling
· Highly precise voltage inspection
· Active balance for heavy current
· Multiple protection for safety
· Practical evaluation of SOC
· Records of historical events
· Better user experience
· Smart BMS interface
· High reliability
Completely Integrated System (for reference only)
FSS introduction
Loop of multiple FSS solution with FDMC
20kW indoor vertical mounted HVAC
Parameters Model | Unit | MC200HCNC1A |
Dimensions, Weight & Mount | ||
External Dimensions (Width x Depth x Height )With Flange | mm | 800×650×2100 |
Weight | kg | 260 |
Mounting Method | Indoor | |
Application | Indoor | |
Environmental Protection & Performance | ||
Working Temperature Range | ºC | -30 to +45 |
Noise Level | dB(A) | 75 |
Refrigerant | R410A | |
RoHS Compliant | Yes | |
Cooling/Heating Capacity | ||
Cooling Capacity@L27(50%)/L35 | kW | 28 |
Heating Capacity | kW | 8 |
Consumption Power | ||
Power input of cooling@l27 (50%)/L35 | kW | 10 |
Heating input power | kW | |
Air supply | ||
air supply volume | m3/h | 6600 |
Power Supply | ||
Power Supply range | V, Hz | 380-415±10%,3N~,50 |
Rated operating voltage - Controller | V, Hz | 380-415,3N~,50 |
Rated operating voltage - Cooling/Heating | Hz | 380-415,3N~,50 |
Current Max. | A | 40 |
Key Components | ||
Controller | Envicool | |
Fans | Telecom Level | |
Compressor | Telecom Level | |
Heater | Telecom Level |
PCS introduction
Sinexcel PWG2-50K-NA 5sets
·Modular design and wide power range in
·single cabinet
·Bi-directional Power Conversion System
·Built-in transformer
·Grid-support functions
·Flexible configuration
·Support PV access
Compliance
UL1741 /UL 9540, CPUC RULE 21,IEEE1547,CSA 22.2
Please reference the datasheet.
EMS
EMS will achieve the load monitor and send command to PCS to adjust the output power to
response load requirement.
Actual scene diagram
Caution
Place the module out of the reach of children and infants.
Do not place the module in microwave ovens or other similar appliances.
Do not remove the product label.
Do not attempt to open or service the battery pack.
Do not expose to temperatures above 80℃.
Do not short-circuit the positive and negative terminals of the battery with wire or other metallic objects.
Do not transport or store the module with metallic items.
Do not expose the module to direct heat or flame, and do not use or store it near a fire or a location, subject to high temperatures. In addition, do not immerse or dampen the module in water, saltwater, or any other liquid.
Do not puncture the module with any sharp objects, hit it with a hammering device or similar device, step on it, drop it or subject it to strong shock.
Do not use module if it is damaged or deformed.
Immediately cease use of the module if it produces strange smells or smokes or becomes abnormally hot.
If the module fluids leak and come into contact with an eye, do not rub the eye and immediately flush it with plenty of water before seeking medical assistance.
Notes
The pictures in the file are only for reference.
We reserve the final explanations of the items in this specification. This proposal is applicable for prototype.
Specifications subject to change without notice