WDLFP-1000KW-1.55MWh specifications

Product Description


System features

  •  Millisecond level response speed of BESS controller;

  •  Multiple ESS control functionalities;

  •  Compatible communication interface with battery management system (BMS);

  •  Proprietary versatile control algorithms and logics;

  •  Control can be realized in either ESS controller or PCS control software;

  •  Built-in transient fault recorder function for fault tracking and system analysis;

  •  Hundreds of communication protocols are supported;

  •  Work with different renewable energy for smoothing the power generation;

  •  Manual operation;

  •  Anti-islanding operation;

  •  Black start/ island operation;

  •  Frequency regulation control;

  •  The other functions required by grid requirement;


716.8V 1000KW/1.55MWh

Please read the user manual carefully before operating!


Module Specifications


No.

Part Number

WDLFP-51.2V11.1K-P

1

Energy storage

11.1KWh

2

Rated Voltage

51.2V/DC

3

Maximum Charge Voltage

57.6V/DC

4

Discharge Cut-off Voltage

40V/DC

5

Configuration

16S7P

6

ESR/AC @1KHz 50% SOC

<10mΩ

7

Max. Continuous Current

140A

8

Max. Power

7.168KW

9

Charge Temperature

0℃~+55℃

10

Discharge Temperature

-20℃~+60℃

11

Recommended Depth of Discharge

5%~90%

12

Maximum Depth of Discharge

100%

13

Operating Humidity

0~90% RH Non-condensing

14

Cells Self-discharge Rate

3% per month

15

Cooling Method

natural cooling

16

Shell Material

Metal

17

Communicate Method

CAN

18

Monitoring Data

Module voltage,SOC,current,temperature,cell’s voltage

19

Output Terminal

Connector

20

Weight

130Kg

21

Dimensions(W*D*H)

690*790*133mm



 Module Drawing


Rack String Specifications

No.

Part Number

WDLFP-716.8V155.4K-R

1

Energy storage

155.4KWh

2

Rated Voltage

716.8V/DC

3

Maximum Charge Voltage

806.4V/DC

4

Discharge Cut-off Voltage

627.2V/DC

5

Configuration

224S7P (14sets above module series connection)

6

ESR/AC @1KHz 50% SOC

<140mΩ

7

Max. Continuous Current

140A

8

Max. Power

100KW

9

Weight

1820Kg

10

Dimensions(W*D*H)

740*860*2165mm



Rack String Dimensions and Layout



Containered Battery Energy Storage System Specifications

No.

Part Number

WDLFP-716.8V1000KW/1.55MWh-C

1

Energy storage

1.554MWh

2

Rated Voltage

716.8V/DC

3

Maximum Charge Voltage

806.4V/DC

4

Discharge Cut-off Voltage

627.2V/DC

5

Configuration

224S7P*10 (10units strings parallel connection)

6

ESR/AC @1KHz 50% SOC

<50mΩ

7

Max. Continuous Current

1400A

8

Max. Power

1000KW

9

Charge Temperature

0℃~+55℃

10

Discharge Temperature

-20℃~+60℃

11

Recommended Depth of Discharge

5%~95%

12

Maximum Depth of Discharge

100%

13

Operating Humidity

0~90% RH Non-condensing

14

Cooling Method

natural cooling

15

Weight

18200Kg (not including container and PCS)

16

Dimensions(W*D*H)

740*860*2165mm*10sets




Unique Balancing Technologies

· Non-destructive active balancing

· High balancing current, almost no heat dissipation

· Balancing regardless of circumstances



Smart Management System

· High accuracy voltage detection

· High accuracy current detection

· High current non-destructive active balance

· High efficiency balancing strategy

· Multi-protection

· Applicable SoC estimation

· High reliability

· Intellectual BMS interface

· Historical event slog




Main Characters of BMS

· Highly precise current temperature

· High efficient balance controlling

· Highly precise voltage inspection

· Active balance for heavy current

· Multiple protection for safety

· Practical evaluation of SOC

· Records of historical events

· Better user experience

· Smart BMS interface

· High reliability




Completely Integrated System (for reference only)



FSS introduction


Loop of multiple FSS solution with FDMC

HVAC specification

20kW indoor vertical mounted HVAC


Parameters Model

Unit

MC200HCNC1A

Dimensions, Weight & Mount



External Dimensions (Width x Depth x Height )With Flange

mm

800×650×2100

Weight

kg

260

Mounting Method


Indoor

Application


Indoor

Environmental Protection & Performance



Working Temperature Range

ºC

-30 to +45

Noise Level

dB(A)

75

Refrigerant


R410A

RoHS Compliant


Yes

Cooling/Heating Capacity



Cooling Capacity@L27(50%)/L35

kW

28

Heating Capacity

kW

8

Consumption Power



Power input of cooling@l27 (50%)/L35

kW

10

Heating input power

kW


Air supply



air supply volume

m3/h

6600

Power Supply



Power Supply range

V, Hz

380-415±10%,3N~,50

Rated operating voltage - Controller

V, Hz

380-415,3N~,50

Rated operating voltage - Cooling/Heating

Hz

380-415,3N~,50

Current Max.

A

40

Key Components



Controller


Envicool

Fans


Telecom Level

Compressor


Telecom Level

Heater


Telecom Level



PCS introduction

Sinexcel PWG2-50K-NA 5sets

·Modular design and wide power range in

·single cabinet

·Bi-directional Power Conversion System

·Built-in transformer

·Grid-support functions

·Flexible configuration

·Support PV access

Compliance

UL1741 /UL 9540, CPUC RULE 21,IEEE1547,CSA 22.2


Please reference the datasheet.


EMS

EMS will achieve the load monitor and send command to PCS to adjust the output power to

response load requirement.



Actual scene diagram

    


Caution

  • Place the module out of the reach of children and infants.

  • Do not place the module in microwave ovens or other similar appliances.

  • Do not remove the product label.

  • Do not attempt to open or service the battery pack.

  • Do not expose to temperatures above 80℃.

  • Do not short-circuit the positive and negative terminals of the battery with wire or other metallic objects.

  • Do not transport or store the module with metallic items.

  • Do not expose the module to direct heat or flame, and do not use or store it near a fire or a location, subject to high temperatures. In addition, do not immerse or dampen the module in water, saltwater, or any other liquid.

  • Do not puncture the module with any sharp objects, hit it with a hammering device or similar device, step on it, drop it or subject it to strong shock.

  • Do not use module if it is damaged or deformed.

  • Immediately cease use of the module if it produces strange smells or smokes or becomes abnormally hot.

  • If the module fluids leak and come into contact with an eye, do not rub the eye and immediately flush it with plenty of water before seeking medical assistance.



Notes

  • The pictures in the file are only for reference.

  • We reserve the final explanations of the items in this specification. This proposal is applicable for prototype.

  • Specifications subject to change without notice



Inquiry

WDLFP-460V230KW-500KWh-20ft

WDLFP-250KW-215KWh Rack specifications

WDLFP-100KW-150KWh Cabinet